home
***
CD-ROM
|
disk
|
FTP
|
other
***
search
/
SGI Developer Toolbox 6.1
/
SGI Developer Toolbox 6.1 - Disc 4.iso
/
public
/
fax
/
src
/
doc
/
telebit
< prev
next >
Wrap
Internet Message Format
|
1994-08-01
|
5KB
From: sainez@Telebit.COM (Jaime Sainez)
Subject: Re: Documentation for Telebit modems in FAX mode?
Here's the Telebit T3000/WorldBlazer (Up to LA7.04c) commands in their
simplest form.
COMMAND DESCRIPTIONS
+FAA, Answer Parameter
+FAA=? 0
+FAA=0
_______________________________________
+FAXERR, T.30 Session Error Report
+FAXERR=<table value>, read only
Valid values: 0-255
Mandatory values: 0,10,20,30,40,50,60,70
_______________________________________
+FBADLIN, Bad Line Threshold
+FBADLIN=? 0
+FBADLIN=0
_______________________________________
+FBADMUL, Error Threshold Multiplier
+FBADMUL=? 0
+FBADMUL=0 .
_______________________________________
+FBOR, Data Bit Order
+FBOR=? 0-3
+FBOR=0
+FBOR=1
+FBOR=2
+FBOR=3
_______________________________________
+FBUF, Buffer Size
+FBUF=0
_______________________________________
+FBUG, Session Message Reporting
+FBUG=? 0,1
+FBUG=0
+FBUG=1
_______________________________________
+FCIG, Local Polling ID String
+FCIG=? (20)(32-127)
+FCIG="<local polling ID string>"
_______________________________________
+FCLASS, Service Class Identification & Selection
+FCLASS=? 0,2
+FCLASS=0
+FCLASS=2
_______________________________________
+FCQ, Copy Quality Checking
+FCQ=? 0
+FCQ=0
_______________________________________
+FCR, Capability to Receive
+FCR=? 0,1
+FCR=0
+FCR=1
_______________________________________
+FCTCRTY, CTC Retry Count
+FCTCRTY=? 0
+FCTCRTY=0
_______________________________________
+FDCC, DCE capabilities parameters
+FDCC=<VR,BR,WD,LN,DF,EC,BF,ST>
+FDCC=? (0,1),(0-3),(0-2),(0-2),(0),(0),(0),(0-7)
+FDCC? 0,3,0,2,0,0,0,0 Default Value
Values:
VR 0,1
BR 0,1,2,3
WD 0,1,2
LN 0,1,2
DF 0
EC 0
BF 0
ST 0,1,2,3,4,5,6,7
_______________________________________
+FDCS, Current Session results
+FDCS=<VR,BR,WD,LN,DF,EC,BF,ST>
+FDCS? 0,0,0,0,0,0,0,0 Default value.
_______________________________________
+FDFFC, Data Compression Format Conversion
+FDFFC=? 0
+FDFFC=0
_______________________________________
+FDIS, Current Session Parameters
+FDIS=<VR,BR,WD,LN,DF,EC,BF,ST>
+FDIS=? (0,1),(0-3),(0-2),(0-2),(0),(0),(0),(0-7)
+FDIS? 0,3,0,2,0,0,0,0 Default value
Values:
VR 0,1
BR 0,1,2,3
WD 0,1,2
LN 0,1,2
DF 0
EC 0
BF 0
ST 0,1,2,3,4,5,6,7
_______________________________________
+FDR, Begin or Continue Phase C Receive Data
+FDR
_______________________________________
+FDT, Data Transmission
+FDT
_______________________________________
+FECM, Error Correction Mode Control
+FECM=? 0
+FECM=0
_______________________________________
+FET, Transmit Page Punctuation
+FET=? 0,1,2,4,5,6
Values:
0
1
2
4
5
6
_______________________________________
+FK, Session Termination
+FK
_______________________________________
+FLID, Local ID String
+FLID=? (20)(32-127)
+FLID="local ID string"
_______________________________________
+FLNFC, Page Length Format Conversion
+FLNFC=? 0
+FLNFC=0
_______________________________________
+FLPL, Indicate Document to Poll
+FLPL=? 0,1
+FLPL=0
+FLPL=1
_______________________________________
+FMDL?, Request Model Identification
+FMDL?
_______________________________________
+FMFR?, Request Manufacturer Identification
+FMFR?
response:
Telebit
_______________________________________
+FMINSP, Minimum Phase C Speed
+FMINSP=? 0-3
+FMINSP=0
+FMINSP=1
+FMINSP=2
+FMINSP=3
_______________________________________
+FPHCTO, DTE Phase C Response Time-out
+FPHCTO=? 0-255
+FPHCTO? 30 Default value.
Range:0 - 255
_______________________________________
+FPTS, Page Transfer Status
+FPTS=? 1-5
+FPTS=1
+FPTS=2
+FPTS=3
+FPTS=4
+FPTS=5
_______________________________________
+FRBC, Phase C Receive Data Block Size
+FRBC=? 0-0
+FRBC=0
_______________________________________
+FREL, Phase C Received EOL Alignment
+FREL=? 0,1
+FREL=0
+FREL=1
_______________________________________
+FREV?, Request Product Revision Identification
+FREV?
_______________________________________
+FSPL, Request to Poll
+FSPL=? 0,1
+FSPL=0
+FSPL=1
_______________________________________
+FTBC, Phase C Trasmit Data Block Size
+FTBC=0
_______________________________________
+FVRFC, Vertical Resolution Format Conversion
+FVRFC=? 0
+FVRFC=0
_______________________________________
+FWDFC, Page Width Format Conversion
+FWDFC=? 0
+FWDFC=0
RESPONSE DESCRIPTIONS
_______________________________________
+FCFR, Indicate Confirmation to Receive
+FCFR
_______________________________________
+FCKG:<string>, Report the Remote ID
+FCKG:"<CIG ID string>" Polling station ID
+FCKG
_______________________________________
+FCON, Facsimile Connection Response
+FCON
_______________________________________
+FCSI:<string>, Report the remote ID
+FCSI:"<CSI ID string>"Called Station ID
+FCSI
_______________________________________
+FDCS, Report DIS/DCS/DTC frame information
+FDCS=<VR,BR,WD,LN,DF,EC,BF,ST>
+FDCS? 0,0,0,0,0,0,0,0 Default value.
_______________________________________
+FHNG, Call Termination with Status
+FHNG:<hang-up status code>
_______________________________________
+FPOLL, Remote Polling Indication
+FPOLL
_______________________________________
+FPTS, Receive and Transmit Page Transfer Status
+FPTS=? 1-5
+FPTS=1
+FPTS=2
+FPTS=3
+FPTS=4
+FPTS=5
_______________________________________
+FTSI:<string>, Report the Remote ID
+FTSI:"<TSI ID string>"Transmit Station ID